Select the three tools used for obtaining a pupil distance
The biggest issue when mis-measuring the pupil distance would be
Digital Measuring units can measure
The biggest error when utilizing a pd ruler is
In measuring for progressive lenses the optician must
Digital Measuring systems came into the market because
Digital measuring systems are not a good option for those who
Digital measuring systems can measure as small as
Traditional lens styles can be
Strabismus is
Reasons you would not utilize a digital measuring system include
Benefits of the digital measuring systems include
Children under ten years of age are
It is important to practice traditional methods because
When measuring for a bifocal vertically, the following tools can be used
Mis-measuring the optical center too high or too low can cause
Elderly patients may not be good candidates for digital measuring because
While not a muscular issue, when using digital measurements people often times
Which of the following would not be a result of human error?
The “wow factor” digital systems offer is important because
Nystagmus is
When the ocular center is placed too high on a minus lens, the following occurs
The patient has an Rx of -3.50. The pd is delivered 3 mm off. How much approximate prism is induced
A customer has an Rx of – 1.75 ou, single vision glasses. Upon evaluation you see that the OC on the right lens is placed 5 mm too high. What is the next step
It is best to do a manual measurement on a customer when
A trait in nystagmus patients that makes digital measuring systems difficult is
What is the term for the standards set for prescription tolerances
Digital systems do not measure
When the prism direction is Base Up what direction is the eye pulled
When the prism direction is base in what direction is the eye pulled
The glasses are delivered 1.50 D of base in prism on a minus lens. The pupil distance is misplaced in what direction
The glasses are finished with 1.5 D of base in prism. Which of the following statements is true?
The ANSI tolerance for vertical prism in a progressive lens with a power of + / –3.37 is
For progressive lenses, when the pupil distance is mis-measured the following could occur
The pupilometer
The pd ruler
When working with patients we need to be observant of
As experts we need to
An Rx calls for 2D base in prism. Upon evaluation of the spectacles are finished with 3D of base in prism. What is the most likely reason for this?
The optical center is